<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15195</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Unload table vacuum did not release in time, check air lines
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Not used in release 2.25
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This error should not occur.
</text></DescriptionText>
</OperatorAction>
<Cause>
During a process, the plate is fed into the bridge (with the bridge belts (cbelt)
running)and then the belts are stopped. Then the unload vacuum is released and the
unload cups retracted and after 1 second the brige belts started again.
The vacuum is is checked beforethe belts are restarted just to make sure that it is
at least below the grip threshold
(uvt), if not then this error is reported, unsolicited, log only.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cfg_uvt.xml</LinkAddress><LinkTitle>NVS: al uvt</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:56 2008 PST
</Updated>
<Links>
</Links>
</Error>